RPX couplings selection

RPX coupling selection to couple an 11.0kW, 1450 rev/min motor to a hammer mill which absorbs 9.6kW running for 12 hours per day with no more than 30 stops / starts per hour. A good shock absorbing spider is required for this heavy-duty application.

The ambient temperature is + 38∘C. The motor shaft is 42mm diameter and the kiln shaft 38mm.

Service factor

From table 1 on page 251, the service factor for this application is 1.75 x 1.2 x 1.0 = 2.1

Design power

The design power is 9.6 x 2.1 = 20.2 kW

RPX coupling Attributes Table

The above selection procedure is based on the following parameters: –

service factor 2.0

30∘C Maximum temperature

Shore 92 insert

  • Pilot bore flanges are in Bold
  • Taper bore flanges art in italics

100 starts per hour maximum

If the parameters are different from the above, selection should be based on power and speed.